- “E0”: Check whether the mainboard cable is removed. If the cables are in good condition, replace the mainboard.
- “E1”: Replace the temperature and humidity sensor of the corresponding model.
- “E2”: Replace the temperature sensor next to the evaporator of the corresponding model.
- “FT”: If it is a new machine that has not been used, please pull out the water plug of the machine first, shake the machine to ensure that there is no water in the water tray, reset the float ball, and power again to see if the problem is solved. If it's a used machine. Remove the water plug at the bottom of the machine, drain the water, and plug it in again.
- “FL”: Pull out the water plug at the bottom of the machine, drain the water and run the machine again; Connect the drain pipe of the machine.
The exhaust pipe of the machine is placed too high to exhaust normally. Please lower the exhaust pipe and do not bend it to ensure that the machine can exhaust smoothly.
Set the setting temperature of the machine lower.
Set the machine temperature lower than the ambient temperature.